LIQUID PHASE EQUIPMENT
Emergency treatment, pilot testing, de-colorization, product purification, wastewater treatment, groundwater treatment, well water treatment, process water treatment.
PLEASE CALL US FOR OTHER SIZE OF LIQUID PHASE EQUIPMENT AT 626-858-1888 OR TOLL FREE AT 877-858-1818

2000 LBS MILD STEEL VESSEL (L-2000)


L-2000 IS fabricated from mild steel . THE UNIT HAS two part Epoxy coatings on the inside and industrial enamel on the outside to give a long service life. 2" steel FPT inlet/outlet fittings on the tip of the vessels are connected to PVC internals for corrosion resistance. l-2000 has forklift access, a screened drain and A top manhole.
 
Specifications
A-Diameter, Outside: 48"
B-Tank Height: 72"
C-Overall Height: 86"
Carbon Weight, Lbs.: 2000
Flow Rate, GPM: 60
Maximum Pressure, psig: 12
Max. design Temp., Deg F: 140

Before l-2000 used for the first time, they should be filled with clean water through the bottom collector, and allowed to degas for a period of 8 to 12 hours. A gentle backwash is recommended to remove carbon fines that
can cause excessive pressure drop through the unit. Multiple units are usually connected in series with testing between the units advised to determine when the first unit needs to be changed out.

Monitoring the contaminant concentration level into the last unit in a series arrangement is the recommended safeguard against having breakthrough in the final outflow. When the concentration of contaminants in the flow
coming out of the lead unit equals the concentration of the flow into the unit, the unit has reached its removal capacity and should be removed from service.

The working life of each unit is dependent upon the type of contaminant in the water as well as its concentration and the liquid flow rate. A pressure relief device is advised to prevent damage to the absorber or cause a failure in the event of excessive pressure buildup.

Backwashing is operating at an elevated pressure, will sometimes provide a temporary lowering of the pressure drop through a unit.

Once the carbon is saturated by contaminants or exhausted, the unit should be taken off line.
If connected in a series mode, the next down stream unit should be moved into the lead position and a fresh unit put at the end of the train.

Please look our selection of LIQUID PHASE ACTIVATED CARBON MEDIA
To purchase replacement carbon or to arrange for a carbon change out please contact us at 626-858-1888